Input Voltage: | 110V-230V | Power: | 4000W |
---|---|---|---|
Maximum Output Corrent: | 100A | Protection Degree: | IP 54 |
Dimensions Carrying Case(WxDxH): | 405*285*340mm | Weight Machine: | 16kg |
Working range | 20-315mm |
Power supply | 110/230V Sihgle Phase 50/60 Hz |
Absorbed power | 4000W |
Max.output curent | 100A |
60% Duty Cycle output | 60A |
Memory capacity | 500 report |
Protection degree | IP 54 |
Weight machine body | ~16 kg (35.5lb) |
Dimensions machine body | 263×240×300mm;10.3"×9.4"×1.8" |
Dimensions transport case | 405×285×340mm; 16"×11.2"×13.4" |
Before performing fusions and before connecting to power outlet, check the following:
NOMINAL TENSION AND FREQUENCY : see technical features (page 7)
OUTLETS AND EXTENTION CABLES: they must be suitable for the power absorbed by machine ( see page 7, 10)
CABLES: isolation has to be intact, they have to be placed away from places where vehicles transit and where they can be damaged .
MACHINE BODY: it has to be isolated and placed steadily.
Keep machine and cables clean and dry. Before cleaning operations disconnect machine from power supply. Use a humid soft cloth with water and alcohol (avoid any kind of solvent).
ELEKTRA is an electronic equipment therefore it has to be handled safely avoiding impacts and sudden temperature changes.
To guarantee correct functioning for as long as possible, operators has to perform frequent checks to the following components :
- Connectors and adapters
- Power cables and fusion cables
- Display
- Mechanical structure (frame, box).
In case of any anomaly machine has to be checked by manufacturer or by an authorized service centre.
In any case machine has to be serviced every 2 years by manufacturer or by an authorized service centre.
Electrical welding machine- ELEKTRA 315 Packing Normal export packing:Inner packing is aluminum case, outside is carton Dimensions:40.5×28.5×34mm N.W:16kg G.W:20kg Electrical welding machine- ELEKTRA 315ApplicationsBefore performing fusions and before connecting to power outlet, check the following:
NOMINAL TENSION AND FREQUENCY : see technical features (page 7)
OUTLETS AND EXTENTION CABLES: they must be suitable for the power absorbed by machine ( see page 7, 10)
CABLES: isolation has to be intact, they have to be placed away from places where vehicles transit and where they can be damaged .
MACHINE BODY: it has to be isolated and placed steadily.
Keep machine and cables clean and dry. Before cleaning operations disconnect machine from power supply. Use a humid soft cloth with water and alcohol (avoid any kind of solvent).
ELEKTRA is an electronic equipment therefore it has to be handled safely avoiding impacts and sudden temperature changes.
To guarantee correct functioning for as long as possible, operators has to perform frequent checks to the following components :
- Connectors and adapters
- Power cables and fusion cables
- Display
- Mechanical structure (frame, box).
In case of any anomaly machine has to be checked by manufacturer or by an authorized service centre.
In any case machine has to be serviced every 2 years by manufacturer or by an authorized service centre.
Press button G to turn machine on.
Machine performs a self testing to check correct functioning.
If testing is ok display will show what’s on side picture *.
If testing reveals and error an error code will be displayed